Laserfiche WebLink
Town of Dover Planning Board 3 June 1, 2018 <br /> <br />compliance on the Master Plan by adding a 100 ft. buffer line from the edge of the Ten Mile <br />River. <br />7. Old Forge Road bisects the project site. The Master Plan and site plan should include pedestrian and <br />vehicular wayfinding. Particular attention should be directed to areas where pedestrians may be <br />crossing Old Forge Road at night and where there may be limited sight distance. <br />As stated in the 5/9/18 letter to the Planning Board, the Site Plan will include pedestrian and <br />vehicular wayfinding for those areas where pedestrians may be crossing Old Forge Road. <br />AKRF continues to recommend this information be incorporated into the Master Plan as well, <br />in order to adequately address pedestrian and vehicular circulation as well as safety <br />considerations under SEQRA. <br />8. The Applicant should consider providing a dry hydrant on the site for fire protection. <br />As stated in the 5/9/18 letter to the Planning Board, the Applicant will provide a dry hydrant in <br />one of the on-site ponds for fire protection. The Applicant should note the location of the dry <br />hydrant as part of the required information on proposed utilities in the Master Plan drawing. <br />9. AKRF recommends that the Applicant provide a large event management plan that addresses <br />parking, circulation, sanitary facilities, noise control, and safety that would address any la rge event <br />held on the property. <br />As stated in the 5/9/18 letter to the Planning Board, no gatherings in excess of 500 people are <br />anticipated, therefore a large event management plan is not required. The Planning Board <br />should consider a cap on the total number of guests for a given event as a condition of the <br />Special Permit. <br />10. The Applicant has indicated that the proposed use may either be a Camp Type I or a Country Inn and <br />Conference Center. The Applicant should provide more detail on proposed use as it relates to the <br />definitions and Special Permit Criteria provided in the Zoning Code. <br />As stated in the 5/9/18 letter to the Planning Board, the approximately 25 proposed cabins, <br />farm stay program, farm-based workshops, and conferences would fall within the Country <br />Inn/Conference Center use definition. The approximately 40 proposed seasonal tent sites fall <br />within the Camp, Type 1 use definition. The Applicant’s 5/9/18 letter includes a summary of <br />each project component in relation to the definitions and Special Permit Criteria in the Zoning <br />Code. AKRF has reviewed this summary and has the following comments on selected areas of <br />the Zoning Code: <br />Country Inn/Conference Center (§145-52.2) <br />§145-52.2-D: The Applicant has indicated that the proposed floor area of the project is <br />approximately 0.25% of the total land area, which is below the maximum 5% stated in the <br />Zoning Code. It is not clear how the 0.25% figure w as calculated, since a full breakdown of <br />proposed floor area (by structure) is yet to be provided for the Planning Board’s review. The <br />Master Plan identifies proposed buildings and their uses, but is still missing information <br />regarding footprint, height, and square footage for each. <br /> §145-52.2-H: The Applicant is requesting that the Planning Board increase the maximum <br />allowable footprint of the proposed food hub building (the largest proposed building in the <br />project) to 5,300 square feet from the maximum footprint of 4,000 square feet required in the <br />RC district. Pursuant to §145-52.2-H-4, the food hub building would be subject to review by <br />the Architectural Review Board (ARB). Architectural plans should be provided to the Planning <br />Board, who also serves as the ARB. <br /> §145-52.2-K: The Applicant has indicated that the proposed “program buildings” will be <br />provided with sprinkler and fire alarm systems as required by state and local building and fire